{"id":5228,"date":"2026-04-12T12:00:33","date_gmt":"2026-04-12T12:00:33","guid":{"rendered":"https:\/\/ingenic.es\/?p=5228"},"modified":"2026-08-04T14:35:06","modified_gmt":"2026-08-04T14:35:06","slug":"sales-netes-en-hospitals-i-laboratoris","status":"publish","type":"post","link":"https:\/\/ingenic.es\/ca\/sales-netes-en-hospitals-i-laboratoris\/","title":{"rendered":"Sales netes en hospitals i laboratoris: difer\u00e8ncies clau"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Sales netes en hospitals i laboratoris: difer\u00e8ncies clau<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Encara que totes mantenen un nivell de contaminaci\u00f3 controlada, les <strong>sales netes en hospitals i laboratoris<\/strong> tenen objectius funcionals oposats: en sanitat es protegeix el pacient, i en <strong>R+D<\/strong>, el proc\u00e9s. Comprendre aquestes difer\u00e8ncies \u00e9s crucial per al disseny, operaci\u00f3 i compliment normatiu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En aquest article analitzem les principals difer\u00e8ncies entre les <strong>sales netes en hospitals i laboratoris<\/strong>, aix\u00ed com els requisits t\u00e8cnics i normatius que ha de complir cadascuna.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Qu\u00e8 \u00e9s una sala neta<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Segons la norma <strong>ISO 14644-1<\/strong>, una sala neta \u00e9s un entorn en qu\u00e8 la concentraci\u00f3 de part\u00edcules en l&#8217;aire es mant\u00e9 dins de l\u00edmits espec\u00edfics.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Aix\u00f2 s&#8217;aconsegueix mitjan\u00e7ant <strong>sistemes de filtraci\u00f3 HEPA\/ULPA<\/strong>, <strong>control del flux d&#8217;aire<\/strong> i <strong>pressions diferencials entre zones<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">El disseny, l&#8217;operaci\u00f3 i el manteniment d&#8217;aquestes sales depenen del seu nivell de neteja (<em>classe ISO<\/em>) i de la naturalesa del proc\u00e9s que es duu a terme al seu interior.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Sales netes en hospitals<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Les <strong>sales netes hospital\u00e0ries<\/strong> s&#8217;instal\u00b7len en \u00e0rees on la seguretat del pacient i l&#8217;esterilitat de l&#8217;entorn s\u00f3n cr\u00edtiques. El seu objectiu principal \u00e9s protegir el pacient i el personal sanitari de la contaminaci\u00f3 microbiana o particulada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00c0rees hospital\u00e0ries que requereixen sales netes:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Quir\u00f2fans d&#8217;alta complexitat.<\/li>\n\n\n\n<li>Sales de trasplantaments i unitats de cremats.<\/li>\n\n\n\n<li>Sales de preparaci\u00f3 de medicaments est\u00e8rils (farm\u00e0cia hospital\u00e0ria).<\/li>\n\n\n\n<li>Laboratoris cl\u00ednics i d&#8217;anatomia patol\u00f2gica.<\/li>\n\n\n\n<li>\u00c0rees d&#8217;esterilitzaci\u00f3 i a\u00efllament.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edstiques t\u00e8cniques:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pressi\u00f3 positiva per impedir l&#8217;entrada de contaminants de l&#8217;exterior.<\/li>\n\n\n\n<li>Filtraci\u00f3 mitjan\u00e7ant HEPA H14, amb un 99,995% d&#8217;efici\u00e8ncia.<\/li>\n\n\n\n<li>Renovacions d&#8217;aire: entre 15 i 60 per hora, segons l&#8217;\u00e0rea.<\/li>\n\n\n\n<li>Control estricte de temperatura (20\u00baC \u2013 24\u00baC) i humitat (40% \u2013 60%).<\/li>\n\n\n\n<li>Materials llisos, no porosos i resistents a la desinfecci\u00f3.<\/li>\n\n\n\n<li>Accessos amb dutxes d&#8217;aire o rescloses per a personal i material.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">En hospitals, la prioritat \u00e9s garantir l&#8217;esterilitat i la bioseguretat de l&#8217;entorn cl\u00ednic.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Sales netes en R+D i control de qualitat (farm\u00e0cia\/biotecnologia)<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Les <strong>sales netes en laboratoris<\/strong> se centren m\u00e9s a protegir el proc\u00e9s o les mostres que al personal. Aquestes instal\u00b7lacions s&#8217;utilitzen en recerca, desenvolupament i control de qualitat on la precisi\u00f3 i la puresa dels resultats s\u00f3n essencials.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tipus de laboratoris que utilitzen sales netes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Laboratoris farmac\u00e8utics i biotecnol\u00f2gics.<\/li>\n\n\n\n<li>Laboratoris de microbiologia i biologia molecular.<\/li>\n\n\n\n<li>Laboratoris de control de qualitat industrial.<\/li>\n\n\n\n<li>Laboratoris \u00f2ptics, electr\u00f2nics i de micromuntatge.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caracter\u00edstiques t\u00e8cniques:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Poden operar amb pressi\u00f3 positiva o negativa, depenent del tipus de material manipulat.<\/li>\n\n\n\n<li>Filtraci\u00f3 mitjan\u00e7ant sistemes HEPA o ULPA segons la classificaci\u00f3 ISO.<\/li>\n\n\n\n<li>Control de flux d&#8217;aire laminar (per a zones cr\u00edtiques) o turbulent (zones auxiliars).<\/li>\n\n\n\n<li>Temperatura estable entre 19\u00baC i 22\u00baC i humitat ajustable segons el proc\u00e9s.<\/li>\n\n\n\n<li>Equips integrats: cabines de seguretat biol\u00f2gica, passamaterials, HVAC dedicats.<\/li>\n\n\n\n<li>Protocols de neteja, acc\u00e9s i vestimenta definits per nivell de risc biol\u00f2gic (BSL).<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L&#8217;objectiu als laboratoris \u00e9s evitar la contaminaci\u00f3 de les mostres o assajos, garantint la fiabilitat dels resultats.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Difer\u00e8ncies clau entre sales hospital\u00e0ries i de laboratori<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Caracter\u00edstica<\/th><th>Sales netes hospital\u00e0ries<\/th><th>Sales netes de laboratori<\/th><\/tr><\/thead><tbody><tr><td>Finalitat<\/td><td>Protegir el pacient i el personal.<\/td><td>Protegir el proc\u00e9s, les mostres o el producte.<\/td><\/tr><tr><td>Pressi\u00f3 diferencial<\/td><td>Positiva (l&#8217;aire surt de la sala).<\/td><td>Positiva o negativa segons el risc.<\/td><\/tr><tr><td>Tipus de contaminant controlat<\/td><td>Microbiol\u00f2gic.<\/td><td>Particulat, qu\u00edmic o biol\u00f2gic.<\/td><\/tr><tr><td>Normativa principal<\/td><td>ISO 14644 + Normes hospital\u00e0ries UNE + GMP farm\u00e0cia hospital\u00e0ria.<\/td><td>ISO 14644 + GMP + BSL (nivells de bioseguretat).<\/td><\/tr><tr><td>Filtraci\u00f3<\/td><td>Filtres HEPA H14.<\/td><td>HEPA H14 o ULPA U15\u2013U17.<\/td><\/tr><tr><td>Monitoratge i tra\u00e7abilitat<\/td><td>Monitoratge microbiol\u00f2gic continu.<\/td><td>Monitoratge de part\u00edcules, gasos o pressi\u00f3 diferencial.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Normatives i certificacions aplicables<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tant hospitals com laboratoris han de complir les seg\u00fcents normes:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ISO 14644-1 \/ -2 \/ -3: classificaci\u00f3 i assajos de neteja.<\/li>\n\n\n\n<li>GMP (<em>Good Manufacturing Practices<\/em>).<\/li>\n\n\n\n<li>EN 12128: laboratoris de microbiologia i biotecnologia.<\/li>\n\n\n\n<li>UNE 100713: quir\u00f2fans i \u00e0rees netes hospital\u00e0ries.<\/li>\n\n\n\n<li>FDA 21 CFR Part 211: producci\u00f3 farmac\u00e8utica.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aquestes regulacions asseguren la qualitat de l&#8217;aire, la seguretat del personal i la tra\u00e7abilitat de l&#8217;entorn controlat.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Disseny i manteniment<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">El disseny d&#8217;ambdues sales ha d&#8217;incloure:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ingenic.es\/ca\/hvac\/\" data-type=\"page\" data-id=\"5001\"><strong>Sistemes HVAC<\/strong> <\/a>independents amb control de pressi\u00f3 i temperatura.<\/li>\n\n\n\n<li>Materials estancs, llisos i resistents a productes qu\u00edmics.<\/li>\n\n\n\n<li>Portes autom\u00e0tiques herm\u00e8tiques.<\/li>\n\n\n\n<li>Superf\u00edcies sense juntes ni cantonades vives.<\/li>\n\n\n\n<li>Manteniment peri\u00f2dic de filtres i sensors.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">El manteniment inclou la neteja validada, la revisi\u00f3 de pressions diferencials, la calibraci\u00f3 de sensors i la revalidaci\u00f3 anual <strong>ISO 14644<\/strong>.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Encara que comparteixen tecnologia, les sales netes hospital\u00e0ries i de laboratori tenen objectius oposats: protegir el pacient o protegir el proc\u00e9s.<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Encara que les <strong>sales netes hospital\u00e0ries i de laboratori<\/strong> comparteixen el mateix principi, controlar la contaminaci\u00f3, els seus objectius i configuracions difereixen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mentre a l&#8217;entorn hospitalari la prioritat \u00e9s protegir el pacient, al laboratori es busca preservar la puresa del proc\u00e9s o mostra.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>ISL Salas Limpias<\/strong>, dissenyem i instal\u00b7lem <strong>sales netes<\/strong> a mida per a hospitals, laboratoris i centres de recerca, complint les normatives <strong>ISO 14644<\/strong>, <strong>GMP<\/strong> i <strong>UNE<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Contacta&#8217;ns per rebre assessorament sobre el disseny, instal\u00b7laci\u00f3 i validaci\u00f3 de la teva propera sala neta hospital\u00e0ria o de laboratori.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sales netes en hospitals i laboratoris: difer\u00e8ncies clau Encara que totes mantenen un nivell de contaminaci\u00f3 controlada, les sales netes en hospitals i laboratoris tenen objectius funcionals oposats: en sanitat es protegeix el pacient, i en R+D, el proc\u00e9s. Comprendre aquestes difer\u00e8ncies \u00e9s crucial per al disseny, operaci\u00f3 i compliment normatiu. En aquest article analitzem les principals difer\u00e8ncies entre les sales netes en hospitals i laboratoris, aix\u00ed com els requisits t\u00e8cnics i normatius que ha de complir cadascuna. Qu\u00e8 \u00e9s una sala neta Segons la norma ISO 14644-1, una sala neta \u00e9s un entorn en qu\u00e8 la concentraci\u00f3 de part\u00edcules en l&#8217;aire es mant\u00e9 dins de l\u00edmits espec\u00edfics. Aix\u00f2 s&#8217;aconsegueix mitjan\u00e7ant sistemes de filtraci\u00f3 HEPA\/ULPA, control del flux d&#8217;aire i pressions diferencials entre zones. El disseny, l&#8217;operaci\u00f3 i el manteniment d&#8217;aquestes sales depenen del seu nivell de neteja (classe ISO) i de la naturalesa del proc\u00e9s que es duu a terme al seu interior. Sales netes en hospitals Les sales netes hospital\u00e0ries s&#8217;instal\u00b7len en \u00e0rees on la seguretat del pacient i l&#8217;esterilitat de l&#8217;entorn s\u00f3n cr\u00edtiques. El seu objectiu principal \u00e9s protegir el pacient i el personal sanitari de la contaminaci\u00f3 microbiana o particulada. \u00c0rees hospital\u00e0ries que requereixen sales netes: Caracter\u00edstiques t\u00e8cniques: En hospitals, la prioritat \u00e9s garantir l&#8217;esterilitat i la bioseguretat de l&#8217;entorn cl\u00ednic. Sales netes en R+D i control de qualitat (farm\u00e0cia\/biotecnologia) Les sales netes en laboratoris se centren m\u00e9s a protegir el proc\u00e9s o les mostres que al personal. Aquestes instal\u00b7lacions s&#8217;utilitzen en recerca, desenvolupament i control de qualitat on la precisi\u00f3 i la puresa dels resultats s\u00f3n essencials. Tipus de laboratoris que utilitzen sales netes: Caracter\u00edstiques t\u00e8cniques: L&#8217;objectiu als laboratoris \u00e9s evitar la contaminaci\u00f3 de les mostres o assajos, garantint la fiabilitat dels resultats. Difer\u00e8ncies clau entre sales hospital\u00e0ries i de laboratori Caracter\u00edstica Sales netes hospital\u00e0ries Sales netes de laboratori Finalitat Protegir el pacient i el personal. Protegir el proc\u00e9s, les mostres o el producte. Pressi\u00f3 diferencial Positiva (l&#8217;aire surt de la sala). Positiva o negativa segons el risc. Tipus de contaminant controlat Microbiol\u00f2gic. Particulat, qu\u00edmic o biol\u00f2gic. Normativa principal ISO 14644 + Normes hospital\u00e0ries UNE + GMP farm\u00e0cia hospital\u00e0ria. ISO 14644 + GMP + BSL (nivells de bioseguretat). Filtraci\u00f3 Filtres HEPA H14. HEPA H14 o ULPA U15\u2013U17. Monitoratge i tra\u00e7abilitat Monitoratge microbiol\u00f2gic continu. Monitoratge de part\u00edcules, gasos o pressi\u00f3 diferencial. Normatives i certificacions aplicables Tant hospitals com laboratoris han de complir les seg\u00fcents normes: Aquestes regulacions asseguren la qualitat de l&#8217;aire, la seguretat del personal i la tra\u00e7abilitat de l&#8217;entorn controlat. Disseny i manteniment El disseny d&#8217;ambdues sales ha d&#8217;incloure: El manteniment inclou la neteja validada, la revisi\u00f3 de pressions diferencials, la calibraci\u00f3 de sensors i la revalidaci\u00f3 anual ISO 14644. Encara que comparteixen tecnologia, les sales netes hospital\u00e0ries i de laboratori tenen objectius oposats: protegir el pacient o protegir el proc\u00e9s. Encara que les sales netes hospital\u00e0ries i de laboratori comparteixen el mateix principi, controlar la contaminaci\u00f3, els seus objectius i configuracions difereixen. Mentre a l&#8217;entorn hospitalari la prioritat \u00e9s protegir el pacient, al laboratori es busca preservar la puresa del proc\u00e9s o mostra. A ISL Salas Limpias, dissenyem i instal\u00b7lem sales netes a mida per a hospitals, laboratoris i centres de recerca, complint les normatives ISO 14644, GMP i UNE. Contacta&#8217;ns per rebre assessorament sobre el disseny, instal\u00b7laci\u00f3 i validaci\u00f3 de la teva propera sala neta hospital\u00e0ria o de laboratori.<\/p>\n","protected":false},"author":2,"featured_media":5227,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[88,103,106],"tags":[],"class_list":["post-5228","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-hospitals","category-sala-neta","category-sanitari"],"acf":[],"_links":{"self":[{"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/posts\/5228","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/comments?post=5228"}],"version-history":[{"count":5,"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/posts\/5228\/revisions"}],"predecessor-version":[{"id":6130,"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/posts\/5228\/revisions\/6130"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/media\/5227"}],"wp:attachment":[{"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/media?parent=5228"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/categories?post=5228"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ingenic.es\/ca\/wp-json\/wp\/v2\/tags?post=5228"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}